Watts to amps calculator

Convert watts to amps or amps to watts for 120 V, 230 V, 240 V or three-phase supplies, and work out energy use in kWh. Formulas and worked examples.

By the Wisiko editorial team · Updated 23 October 2026 · 3 min read

Result
—
Energy used
—

Single phase: P = V × I × PF. For 400 V three-phase, P = √3 × V × I × PF (handled automatically).

Was this calculation useful?
Key points
  • Single phase: amps = watts ÷ volts for resistive loads such as heaters and kettles.
  • A 1,500 W space heater on a 120 V US circuit draws 12.5 A; a 3,000 W UK kettle on 230 V draws about 13 A.
  • Watts measure instantaneous power; kilowatt-hours measure energy over time, which is what you pay for.

The formulas

  • Watts = volts × amps × power factor
  • Amps = watts ÷ (volts × power factor)
  • kWh = watts × hours ÷ 1,000

The power factor is 1 for resistive loads that turn electricity into heat: heaters, kettles, toasters, ovens. Motors and some electronic power supplies have a power factor below 1; it is sometimes printed on the rating plate.

For a three-phase 400 V supply, power = √3 × 400 × amps × power factor. The calculator applies the √3 factor automatically when you choose 400 V.

Worked examples

ApplianceVoltageCurrent
Space heater 1,500 W (US)120 V12.5 A
Kettle 3,000 W (UK)230 V13.0 A
Electric radiator 2,000 W (Europe)230 V8.7 A

Quick reference: amps by wattage

Resistive loads (power factor 1). Amps = watts ÷ volts.

Power120 V230 V240 V
100 W0.83 A0.43 A0.42 A
500 W4.2 A2.2 A2.1 A
700 W5.8 A3.0 A2.9 A
1,000 W8.3 A4.3 A4.2 A
1,500 W12.5 A6.5 A6.3 A
2,000 W16.7 A8.7 A8.3 A
3,000 W25.0 A13.0 A12.5 A
9,500 W (electric shower)—41.3 A39.6 A

Which voltage should I use?

  • United States and Canada: 120 V for standard outlets; large appliances (dryers, ranges) often use 240 V circuits.
  • United Kingdom: the declared supply is 230 V, with a permitted variation of +10% / −6% (about 216–253 V) under regulation 27 of the Electricity Safety, Quality and Continuity Regulations 2002. Many appliances are still described as 240 V; the difference changes the current by only about 4%.
  • Continental Europe: 230 V single phase, 400 V for three-phase supplies.

Watts versus kilowatt-hours

Watts tell you how fast an appliance uses energy. What you pay for is energy: power multiplied by time, in kWh. A 2,000 W heater running for 30 minutes uses 1 kWh, the same as a 10 W LED bulb left on for 100 hours. Our explainer watts vs kilowatt-hours goes further, and the appliance running cost calculator turns kWh into money.

UK plug fuses: 3 A or 13 A?

Electrical Safety First explains that UK plugs are now standardised on 3 A or 13 A fuses. Appliances rated from 700 W to 3,000 W — the maximum rating of a wall socket — should have a 13 A fuse; a 3 A fuse suits low-power items such as lamps and TVs. At 230 V, 700 W is about 3 A, which is where the dividing line comes from. Always replace a blown fuse with one of the same rating.

Big loads need their own circuit

A 3 kW kettle is close to the limit of one socket. Anything bigger is hard-wired on a dedicated circuit: an electric shower is the classic example. Mira’s installation guide for its Jump shower lists 9.5 kW at 240 V (8.7 kW at 230 V) on a 40 A circuit breaker and 10.8 kW (9.9 kW at 230 V) on 45 A. Note that the power of a heating element falls with the square of the voltage: (230 ÷ 240)² ≈ 0.92. See what that means for the bill in our electric shower running cost calculator.

Safety

This converter gives estimates. Choosing a cable size, breaker or socket is governed by wiring regulations (the NEC in the US, BS 7671 in the UK): if in doubt, ask a qualified electrician. Never exceed the rating of an extension lead or adapter.

Frequently asked questions

How many amps is 3,000 watts?

At 230 V, 3,000 W ÷ 230 V ≈ 13 A, which is why 3 kW is the practical limit for a UK 13 A socket. At 120 V it would be 25 A, too much for a standard US outlet.

How many amps does a 1,500 W heater draw?

1,500 W ÷ 120 V = 12.5 A in the US or Canada; on 230 V it is about 6.5 A.

Should I use 230 V or 240 V in the UK?

The UK declared supply voltage is 230 V, allowed to vary from 10% above to 6% below (about 216 to 253 V). Use 230 V unless you have measured your own supply; the result changes by only about 4%.