How much does an electric water heater cost to run?
DOE basis: a resistance tank uses ≈ 3,437 kWh/yr (≈ $624 at 18.16¢), an ENERGY STAR heat pump ≈ 984 kWh. Calculate yours by gallons per day and UEF.
- Electricity per year
- —
- Per month
- —
- Per day
- —
- Saving vs resistance tank
- —
Benchmarks (yearly cost at your tariff)
- Resistance tank, DOE basis (3,437 kWh)
- —
- ENERGY STAR heat pump (984 kWh)
- —
- French tank, ADEME measured median (1,179 kWh)
- —
Formula: kWh/yr = 3,437 × 0.95 ÷ UEF × (gallons per day ÷ 55), calibrated on DOE FEMP purchasing guidance (May 2024: 20,075 gallons/yr; resistance tank UEF 0.95 = 3,437 kWh; ENERGY STAR UEF 3.3 = 984 kWh). 1 US gallon = 3.785 litres. Results are indicative estimates based on the values you enter. Always check your appliance labels, your tariff and the manufacturer’s data.
- On the DOE test basis (20,075 gallons a year, about 55 gallons/day), a standard electric resistance tank (UEF 0.95) uses about 3,437 kWh a year: roughly $624 at the US average residential price (18.16¢/kWh, EIA August 2026).
- A heat pump water heater at the ENERGY STAR level (UEF 3.3) needs about 984 kWh for the same hot water (≈ $179), and the best certified model (UEF 3.93) about 826 kWh.
- Usage drives the bill: at 38 gallons/day a resistance tank needs about 2,375 kWh (≈ $431); at 84 gallons/day about 5,250 kWh (≈ $953).
- For comparison, France’s ADEME measured a median of 1,179 kWh/yr for 42 electric tanks in real homes (2023–2024).
Choose a water heater type (or type the UEF from its EnergyGuide label or spec sheet) and your hot water use per day. The calculator returns yearly, monthly and daily cost at your tariff, and the saving compared with a standard resistance tank. If you already know the yearly kWh, switch to the second mode.
Where the numbers come from
The U.S. Department of Energy’s Federal Energy Management Program (FEMP) compares water heaters using the federal test method (10 CFR 430, appendix E) for a unit delivering 20,075 gallons of hot water a year, about 55 gallons a day:
| Water heater | UEF | kWh per year | At 9.9¢ (FEMP) | At 18.16¢ (US avg, Aug 2026) | At 26.32p (UK cap) |
|---|---|---|---|---|---|
| Electric resistance tank (≤ 55 gal) | 0.95 | 3,437 | $340 | ≈ $624 | ≈ £905 |
| Heat pump, ENERGY STAR level | 3.3 | 984 | $97 | ≈ $179 | ≈ £259 |
| Best available heat pump (June 2024 list) | 3.93 | 826 | $82 | ≈ $150 | ≈ £217 |
FEMP’s 9.9¢/kWh is the average price at federal facilities; households pay more, so we recalculated at EIA’s residential average. The UK column applies the Ofgem price cap unit rate to the same US test volume, for scale only.
Hot water use matters more than tank size
FEMP also publishes savings at four daily usage levels. The calculator scales the 55-gallon figures in proportion, which reproduces FEMP’s table to within 0.5%:
| Daily hot water | Resistance tank | ENERGY STAR heat pump | Saving at 18.16¢ |
|---|---|---|---|
| 10 gal (≈ 38 L) | ≈ 625 kWh | ≈ 180 kWh | ≈ $81/yr |
| 38 gal (≈ 144 L) | ≈ 2,375 kWh | ≈ 684 kWh | ≈ $307/yr |
| 55 gal (≈ 208 L) | ≈ 3,437 kWh | ≈ 989 kWh | ≈ $445/yr |
| 84 gal (≈ 318 L) | ≈ 5,249 kWh | ≈ 1,511 kWh | ≈ $679/yr |
FEMP’s own savings figures for these four levels are 446, 1,695, 2,453 and 3,746 kWh a year.
Heat pump water heaters: modes matter
According to FEMP, a heat pump water heater in efficiency or hybrid mode runs at an energy factor of 2.0 or higher, while electric resistance mode drops to about 0.90 — so use that mode sparingly. In efficiency mode the resistance elements only come on when the surrounding air is at or below 45 °F or at or above 110 °F. FEMP recommends 120 °F for most homes and notes that the unit’s filter needs regular cleaning.
Outside the US
UEF is a US rating. In the UK, a hot water cylinder with an immersion heater behaves like the resistance case; the most reliable input is the kWh you actually use (from a smart meter or a dedicated circuit), entered in the second mode. In France, ADEME’s panel of 100 homes measured a median of 1,179 kWh a year for 42 electric storage tanks (middle half 766–1,674 kWh), well below the US test basis; the panel measures real homes rather than a standard test draw. See our French guide: chauffe-eau électrique.
Ways to cut the cost
- Use less hot water — the bill is roughly proportional to gallons drawn.
- Choose a heat pump model when replacing a resistance tank, if the location suits it — FEMP notes its exhaust air can make the space colder in winter.
- Set the thermostat sensibly (FEMP suggests 120 °F for most homes) and check the setting after maintenance.
- Vacation mode on heat pump models lowers standby losses while you are away.
Whole-home context: average household electricity usage. Heating: heating cost by fuel and heat pump vs electric heater.
In the UK or Ireland with a hot water cylinder in litres and a 3 kW element? Use the immersion heater running cost calculator, which includes cylinder standing losses and off-peak (Economy 7) heating.
Frequently asked questions
How many kWh does an electric water heater use per year?
On the U.S. DOE test basis of about 55 gallons of hot water a day, a standard electric resistance tank (UEF 0.95) uses about 3,437 kWh a year and an ENERGY STAR heat pump water heater (UEF 3.3) about 984 kWh, according to DOE’s Federal Energy Management Program. Lower or higher hot water use scales these figures roughly in proportion.
How much does it cost to run a 50-gallon electric water heater?
The yearly cost depends mainly on how much hot water you draw. At 55 gallons a day and the US average residential price of 18.16¢/kWh (EIA, August 2026), a resistance tank costs about $624 a year and a heat pump model at the ENERGY STAR level about $179.
What is UEF on a water heater?
Uniform Energy Factor is the DOE efficiency rating measured with the federal test procedure (10 CFR 430, appendix E). Higher is better: FEMP’s comparison uses 0.95 for a standard electric resistance tank and 3.3 for the ENERGY STAR heat pump level.
Sources
- U.S. DOE FEMP – Purchasing Energy-Efficient Residential Water Heaters (updated May 2024)
- 10 CFR Part 430, Subpart B, Appendix E (LII): Uniform test method for water heaters
- U.S. EIA – Electricity Monthly Update, data for August 2026
- Ofgem – Energy price cap unit rates (1 October to 31 December 2026)
- ADEME – Panel Elecdom, measured yearly electricity use of household appliances (2023-2024)