How much does an immersion heater cost to run?

A 3 kW immersion heater costs about 79p an hour at the UK price cap. Heating a 150-litre tank from 10 to 60 °C takes 8.7 kWh: about £2.30. Calculate yours.

By the Wisiko editorial team · Updated 6 November 2026 · 3 min read

Estimated cost per year
—
One full heat-up
—
Heat-up time
—
Element running, per hour
—
Per day
—
Per month
—
Electricity per year
—
Of which standing losses
—

Formula: kWh per heat-up = litres × 4.186 × (stored − cold °C) ÷ 3,600, plus the cylinder's declared standing loss for each day it is kept hot. An immersion element turns almost all its electricity into heat, so no efficiency factor is applied. Typical losses are declared values for one manufacturer's direct (electric) cylinders; older or poorly insulated tanks lose more. Results are indicative estimates based on the values you enter. Always check your appliance labels, your tariff and the manufacturer’s data.

Was this calculation useful?
Key points
  • Most UK immersion heaters are 3 kW: while the element is on it uses 3 kWh an hour, about 79p an hour at the Ofgem cap (26.32p/kWh, 1 Oct–31 Dec 2026).
  • Heating a full 150-litre cylinder from 10 °C to 60 °C needs about 8.7 kWh: roughly 2 h 54 min of element time and £2.30.
  • A well-insulated 150 L electric cylinder also loses about 1.5 kWh a day just staying hot (declared standing loss): about £147 a year on its own.
  • One full heat-up a day plus losses comes to about 3,740 kWh, or £985 a year on a single-rate tariff. Heating overnight on an off-peak (Economy 7) rate is the main way to cut this.

Choose your cylinder size (it fills in the volume and a typical declared heat loss), check the element power on the immersion heater, then enter how many full tanks of hot water you use a day. Using half a tank a day? Enter 0.5. The calculator shows the cost of one heat-up, the time it takes, and the cost per day, month and year at the UK price cap or your own tariff.

How the cost of an immersion heater is worked out

An immersion heater is a simple resistance element: almost all the electricity it uses becomes heat in the water, so the running cost depends on how much water you heat, by how many degrees, and how much heat the tank loses while it waits.

  • Energy to heat the water: litres × 4.186 × temperature rise ÷ 3,600 = kWh. For 150 L heated by 50 °C that is 8.72 kWh.
  • Standing losses: a hot cylinder slowly loses heat through its insulation. Manufacturers declare this in kWh per 24 hours on the energy label or data sheet. For World Heat’s direct (electric) unvented cylinders it ranges from 0.96 kWh/24 h for 90 L to 2.34 kWh/24 h for 300 L. Other brands publish their own figure on the cylinder label or data sheet: enter it if you know it.
  • Price: multiply the total kWh by your unit rate. On a multi-rate tariff, the calculator blends your off-peak and peak rates according to the share of heating done at night.
Cylinder (direct, electric)One heat-up 10 → 60 °CTime at 3 kWCost at 26.32pDeclared loss per day
120 L6.98 kWh2 h 20 min£1.841.24 kWh
150 L8.72 kWh2 h 54 min£2.301.53 kWh
180 L10.47 kWh3 h 29 min£2.751.78 kWh
210 L12.21 kWh4 h 04 min£3.212.03 kWh

Economy 7 and off-peak heating

If your home has a dual-element immersion or a timer and a multi-rate meter, the main element can heat the tank overnight at the off-peak rate. Ofgem’s price cap applies to the average of multi-rate tariffs, but it does not publish a single Economy 7 night rate, so enter the off-peak rate from your own bill and the share of heating done at night. Citizens Advice points out that the boost element uses the peak rate, so avoid boosting unless you really need hot water during the day.

Five ways to cut the cost

  1. Use a timer so the water is heated shortly before you need it, not all day.
  2. Heat off-peak if you have a multi-rate tariff.
  3. Insulate the cylinder and the first metre of pipework. Older tanks with a loose jacket lose more than the declared values above.
  4. Keep the thermostat at 60 °C, not higher: hotter storage raises losses, while going below 50 °C is a legionella risk.
  5. Compare with your other options: if you also have a gas boiler, see the gas central heating cost per hour calculator and the yearly heating fuel cost comparison; for an instant shower, see the electric shower running cost calculator. For warming a bathroom briefly instead of reheating the whole cylinder, a heated towel rail or a small oil-filled radiator uses far less than a full tank reheat.

If you are in the US and have a tank-style electric water heater rated in gallons and UEF, use our electric water heater cost calculator instead.

Frequently asked questions

How much does an immersion heater cost to run per hour?

Multiply the element power in kW by your unit rate. A standard 3 kW immersion uses 3 kWh an hour while it is heating: about 79p at the Ofgem cap of 26.32p/kWh (Which? and the Centre for Sustainable Energy both quote about 78p at 26p). In Ireland, at Eurostat's average household price of €0.3871/kWh for the first half of 2026, the same hour costs about €1.16.

How long does an immersion heater take to heat a tank?

It depends on the volume and how cold the water is. Each litre needs 4.186 kJ per degree, so a 150 L tank heated from 10 °C to 60 °C needs about 8.7 kWh, which a 3 kW element delivers in about 2 hours 54 minutes. A 180 L tank needs about 10.5 kWh, or 3.5 hours. If you only used part of the tank, the reheat is shorter.

Is it cheaper to leave the immersion heater on all the time?

No. Once the tank is hot, the thermostat only switches the element back on to replace heat that leaks out of the cylinder or is drawn off, but you pay for those standing losses all day and night. Which? advises against leaving it on constantly and recommends a timer, ideally set for cheaper off-peak hours if you have an Economy 7 type tariff. Citizens Advice also warns that the boost button heats water at the more expensive peak rate.

What temperature should an immersion heater be set to?

The HSE says hot water should be stored at 60 °C or more to kill legionella bacteria, and Which? says the thermostat should not be set below 50 °C. Turning it down further saves only a little and is a health risk; reducing the volume you heat and insulating the tank are safer savings.

Why is your yearly figure different from the Which? example?

Which? estimates about £1,715 a year for a 180 L tank heated from 10 °C to 60 °C twice a day, counting three hours of a 3 kW element per heat-up at 26.11p/kWh. The physics for that tank gives about 10.5 kWh per heat-up rather than 9 kWh, and standing losses come on top, so the calculator gives a higher figure for the same use. Most homes do not reheat a full tank twice a day: entering your real number of heat-ups matters more than anything else.

Sources

  1. Which? – Immersion heaters explained (1 June 2026: typical 3 kW element, cost per hour, timer and temperature advice)
  2. Centre for Sustainable Energy – How much electricity am I using? (immersion heater 3,000 W, cost per hour)
  3. Citizens Advice – Using storage heaters and immersion heaters (off-peak timer, boost element)
  4. HSE – Legionella: things to consider for hot and cold water systems (store hot water at 60 °C or more)
  5. World Heat – Domestic cylinders quick reference (SuperFlow Direct standing heat losses in kWh/24 h; data updated 21 October 2026)
  6. Ofgem – Energy price cap unit rates (1 October to 31 December 2026)
  7. Eurostat – Electricity prices for household consumers, first half of 2026 (nrg_pc_204)

Related

Calculator

How much does an electric water heater cost to run?

DOE basis: a resistance tank uses ≈ 3,437 kWh/yr (≈ $624 at 18.16¢), an ENERGY STAR heat pump ≈ 984 kWh. Calculate yours by gallons per day and UEF.

Calculator

How much does an electric shower cost to run?

A 9.5 kW electric shower costs about 3.8p a minute and 29p for a 7.5-minute shower at the UK price cap, against about 20–22p from a gas combi. Calculate yours.

Calculator

How much does a heated towel rail cost to run?

200 W × 4 h × 180 days ≈ 144 kWh (≈ £38 at the UK cap). Calculate by wattage, hours and season.

Energy

How much does it cost to run a space heater?

US: ~27¢/h for 1,500 W at EIA Aug 2026 rates; UK: Which? averages 33p oil-filled, 48p convector, 60p fan. Thermostat cuts real cost. Calculator.

Calculator

How much does an oil-filled radiator cost to run?

Oil-filled radiator: Which? average 33p/h on high (vs 60p fan). At Ofgem cap, 1.5 kW ≈39p/h max, 2 kW ≈53p. Heat lingers ~30 min after off. Calculator.

Calculator

How much does gas central heating cost per hour?

A combi boiler costs £2.15 an hour flat out (27 kWh of gas at the Ofgem cap) and 43–63p at its lowest setting. A typical home averages £2.37 a day.

Calculator

How much does heating cost by fuel type?

Heating oil costs about 11.2p per kWh of fuel (12.45p of useful heat) in Nov 2026 vs 7.97p for gas under the Ofgem cap. Oil vs gas vs pellets calculator.

Calculator

Appliance running cost calculator