How much does gas central heating cost per hour?
A combi boiler costs £2.15 an hour flat out (27 kWh of gas at the Ofgem cap) and 43–63p at its lowest setting. A typical home averages £2.37 a day.
- Gas used per hour
- —
- Range for this boiler (minimum → full rate)
- —
- Heating per day (gas only)
- —
- Per day incl. standing charge
- —
- Per week
- —
- Per month (30 days)
- —
Formula: gas kWh per hour = gross input (kW) × firing rate; cost = kWh × unit rate. Volume uses the 38.7 MJ/m³ gross calorific value Ideal quotes for its gas rates (m³/h = kW × 3.6 ÷ 38.7). The standing charge is the gas one only and is due even when the boiler is off. The boiler's own electricity (pump, fan) is not included: a few pence a day. Results are indicative estimates based on the values you enter. Always check your appliance labels, your tariff and the manufacturer’s data.
Check it with your gas meter
- Per hour
- —
- Cost per hour at your rate
- —
- Implied average firing rate
- —
Bill formula prescribed by the Gas (Calculation of Thermal Energy) Regulations 1996, as set out by GOV.UK: m³ (imperial: hundreds of ft³ × 2.83) × calorific value × 1.02264 ÷ 3.6 = kWh.
- The cost per hour depends on how hard the boiler fires, not on the number in its name. Popular “24”, “30” and “35 kW” combis (Ideal Logic Max) are all limited to 27.0 kW of gas input for central heating; the bigger number is the hot-water rating.
- Flat out, that is 27 kWh of gas an hour (about 2.5 m³): £2.15 an hour at the Ofgem cap of 7.97p/kWh (1 Oct–31 Dec 2026, incl. VAT). At its lowest setting the same boiler burns 5.4–7.9 kWh: 43p to 63p an hour.
- A boiler only runs flat out while warming a cold home; then it modulates down or switches off until the thermostat calls again. Ofgem's typical household uses 9,500 kWh of gas a year, about 26 kWh a day on average: £2.37 a day including the 29.68p standing charge.
- For your real figure, read the gas meter before and after an hour of heating only: the calculator converts m³ or cubic feet to kWh with the official bill formula.
Pick your boiler (or type the gas input from its data plate), set the average firing rate and how many hours a day the heating is on, and the calculator shows the cost per hour, day, week and month at the Ofgem price cap or your own tariff. If you can, use the meter check underneath: an hour of real readings beats any estimate.
Why the boiler size on the box is not what you pay for
Combi boilers are sold as “24 kW”, “30 kW” or “35 kW”, but that figure is usually the hot-water output. For central heating, many models are capped lower. In Ideal’s Logic Max Combi2 manual (November 2025), all three sizes have the same maximum central-heating input:
| Ideal Logic Max Combi2 | Heating input, max (gross) | Heating input, min (gross) | Hot-water input, max (gross) | Gas rate at max heating |
|---|---|---|---|---|
| C24 | 27.0 kW | 5.4 kW | 27.0 kW | 2.512 m³/h |
| C30 | 27.0 kW | 6.7 kW | 33.7 kW | 2.512 m³/h |
| C35 | 27.0 kW | 7.9 kW | 39.3 kW | 2.512 m³/h |
Manuals list both a net and a gross figure (24.3 kW net = 27.0 kW gross here). Use the gross one: UK gas bills are calculated from the gross calorific value of the gas, so a boiler burning 27.0 kW gross for an hour puts 27 kWh on your bill.
Cost per hour at different firing rates
At the Ofgem cap for 1 October to 31 December 2026 (gas 7.97p/kWh including 5% VAT), for a boiler with a 27 kW gross heating input:
| Firing rate | Gas per hour | Cost per hour | 5 hours | 12 hours | 24 hours |
|---|---|---|---|---|---|
| 100 % (warming a cold house) | 27 kWh | £2.15 | £10.76 | £25.82 | £51.65 |
| 75 % | 20.25 kWh | £1.61 | £8.07 | £19.37 | £38.73 |
| 50 % | 13.5 kWh | £1.08 | £5.38 | £12.91 | £25.82 |
| 25 % | 6.75 kWh | 54p | £2.69 | £6.46 | £12.91 |
The daily gas standing charge (29.68p) comes on top, whatever you use. These are upper bounds for each rate: once the rooms reach the thermostat setting, the boiler turns down to its minimum or stops firing altogether, so real hours cost less. A whole day at 100 % would mean the house never warms up, which points to an undersized boiler, open windows or a fault.
What a typical home actually uses
Ofgem’s typical domestic consumption values, revised from July 2026, put annual gas use at 6,000 kWh (low), 9,500 kWh (medium) and 14,000 kWh (high). These include hot water and, in some homes, a gas hob, and are averaged over a normal-weather year.
| Ofgem usage level | Gas per year | Average per day | Cost per day incl. standing charge | Cost per year |
|---|---|---|---|---|
| Low | 6,000 kWh | 16.4 kWh | £1.61 | £587 |
| Medium | 9,500 kWh | 26.0 kWh | £2.37 | £865 |
| High | 14,000 kWh | 38.4 kWh | £3.35 | £1,224 |
So a medium-use home burns, on average across the year, the equivalent of about one hour of a combi boiler at full heating rate per day. In winter it is more, in summer (hot water only) far less. A single 7.5-minute mixer shower on a combi uses about 2.5–2.8 kWh of gas (about 20–22p); see how that compares with an electric shower.
Measure your own boiler in one hour
- Switch off the hot water and avoid using the gas hob for the test.
- Note the black digits on the gas meter, run the heating for an hour, then read it again.
- Enter the difference in the meter check: the calculator applies the formula prescribed by the Gas (Calculation of Thermal Energy) Regulations 1996, as explained by GOV.UK (m³ × calorific value × 1.02264 ÷ 3.6). Imperial meters read in hundreds of cubic feet, which are multiplied by 2.83 first.
It also shows the average firing rate your reading implies, which you can enter in the main calculator to estimate a day, week or month.
Ways to cut the hourly cost
- Set the room thermostat to the lowest comfortable temperature, usually 18–21 °C. The Energy Saving Trust estimates that turning it down from 22 °C to 21 °C saves about £120 a year in Great Britain.
- Use the timer: heat the home when you are in, starting about half an hour before you get up. With a boiler, leaving the heating on all day costs more.
- Don’t turn the thermostat up to warm up faster: the boiler heats at the same speed, it just overshoots.
- Heating one room only? Compare with our space heater running cost calculator or a heated throw or electric blanket, which cost pence an hour to warm one person.
- Comparing fuels or a heat pump? See the heating cost by fuel calculator (with an oil vs gas vs heat pump table for Ofgem’s low, medium and high gas users) and the heat pump vs electric heater calculator.
Ofgem will announce the price cap for January to March 2027 by 25 November 2026; this page will be updated with the new unit rate and standing charge.
Frequently asked questions
How much does it cost to run gas central heating for 1 hour in the UK?
Multiply the gas the boiler burns in that hour by your unit rate. A typical combi firing at its full heating rate of 27 kW (gross) uses 27 kWh: £2.15 at the Ofgem cap of 7.97p/kWh. Running at half rate it is about £1.08, and at its minimum (5.4 kW for an Ideal Logic Max C24) about 43p. Most hours are somewhere in between, because the boiler turns down or stops once rooms reach the thermostat setting.
How much gas does a 24 kW, 30 kW or 35 kW combi boiler use per hour?
On central heating, often the same. In Ideal's Logic Max Combi2 range all three sizes have a maximum heating input of 24.3 kW net, or 27.0 kW gross, which is 2.512 m³ of gas an hour. The headline size is the hot-water output: when running a hot tap at full flow the C30 burns up to 33.7 kW gross (3.135 m³/h) and the C35 up to 39.3 kW (3.657 m³/h), which is £2.69 and £3.13 per hour of full-flow hot water. Check your own boiler's data plate or manual for its heating input.
How much does gas central heating cost per day?
On average across the year, Ofgem's typical-use household (9,500 kWh of gas a year for all uses, including hot water) uses about 26 kWh a day: £2.07 of gas plus the 29.68p daily standing charge, so £2.37 a day. Low users (6,000 kWh) average about £1.61 a day and high users (14,000 kWh) about £3.35. Winter days are higher than this average and summer days lower.
Is it cheaper to leave the heating on low all day?
Not with a gas boiler. The Energy Saving Trust says keeping the heating on all the time uses more energy and costs more; it is better to have the boiler come on when you need it, for example half an hour before you get up. The Centre for Sustainable Energy calls the all-day idea a myth and adds that turning the thermostat up does not heat the house faster. Heat pumps are the exception: they work best running steadily.
How much electricity does a gas boiler use per hour?
Very little compared with the gas. Ideal declares an auxiliary electricity use of 0.044 kW at full load for the Logic Max C24 (0.028 kW for the C30 and C35) and a maximum power consumption of 94–110 W. At 26.32p/kWh that is roughly 1p to 3p per hour of running.
How do I convert my gas meter reading to kWh?
Subtract the old reading from the new one. For an imperial meter, multiply the hundreds of cubic feet by 2.83 to get m³. Then multiply by the calorific value on your bill (around 39.5 MJ/m³), by 1.02264 for temperature and pressure, and divide by 3.6. One cubic metre at 39.5 MJ/m³ is about 11.2 kWh, or 89p at 7.97p/kWh.
Sources
- Ideal Heating – Logic Max Combi2 C24/C30/C35 Installation & Servicing manual, November 2025 (tables 2–3: gas input gross/net, gas rate m³/h, ErP data)
- Ofgem – Energy price cap unit rates and standing charges (gas 7.97p/kWh, 29.68p/day, 1 October to 31 December 2026)
- Ofgem – Review of typical domestic consumption values, decision (May 2026: gas 6,000 / 9,500 / 14,000 kWh)
- GOV.UK (Office for Product Safety and Standards) – Gas meter readings and bill calculation
- Energy Saving Trust – When should I put my heating on? (thermostat 18–21 °C, boilers and all-day heating)
- Centre for Sustainable Energy – Energy saving myths (reviewed July 2026)